Your radio product needs EMC testing before it can carry a CE mark. EN 301 489 is the standard series that testing follows. In May 2025, the European Commission changed which versions of the series count under the law, and one of those versions will drop off the list on 15 November 2026. This guide shows you which part fits your product and what the listing still leaves on your desk.

  • The EU law that puts EMC on your radio product
  • The parts of EN 301 489 that count right now
  • The two notices that limit every listing
  • The test levels your hardware has to survive
  • The inputs your lab needs before you book a chamber

Where the EMC Rule Comes From

The Radio Equipment Directive (RED) 2014/53/EU sets the rule. Article 3(1)(b) asks your product for “an adequate level of electromagnetic compatibility as set out in Directive 2014/30/EU.” You prove that through the RED. You do not file separately under the EMC Directive.

Two more articles shape how you plan the work. Article 17(2) lets you pick internal production control, so no notified body has to sign off your EMC. Article 16 gives you a presumption of conformity only when the standard you used appears in the Official Journal.

Your QuestionThe AnswerWhere It Says So
What requires EMC performance?Article 3(1)(b)Directive 2014/53/EU
Which route can I use for EMC?Internal production control, Annex IIArticle 17(2)
What earns a presumption of conformity?A reference printed in the Official JournalArticle 16
Where does that list live?Implementing Decision (EU) 2022/2191, amended six times sinceOJ L 289, 10 November 2022

Which Parts Count Right Now

The Commission lists parts, not the series. It never lists EN 301 489-1 on its own. Each part refers to EN 301 489-1 V2.2.3, dated November 2019, for its test methods. That is why your quote lists a part number along with the common standard.

Five Parts Joined the List in May 2025

Implementing Decision (EU) 2025/893 of 14 May 2025 added five entries at once. Check your part number and version against this table before your lab writes the test plan.

PartEquipment It CoversListed VersionAdded By
-3Short-range devicesV2.3.22025/893
-12Very small aperture terminalsV3.2.12022/2191
-17Broadband and wideband data systems: 2.4 GHz and 5 GHz RLAN; 6 GHz WAS/RLAN; 60 GHz MGWSV3.3.12025/893
-19Receive-only mobile earth stationsV2.2.12025/893
-20Mobile earth stationsV2.2.12022/2191
-28Wireless digital video linksV2.1.12025/1741
-52Cellular communication user equipmentV1.3.12025/893
-54Ground-based aeronautical and meteorological radarsV1.1.12025/893

Cellular Files Face a 2026 Deadline

EN 301 489-52 V1.2.1 still sits on the list today. Point 2 of the 2025/893 annex deletes that row on 15 November 2026. If you sell cellular user equipment, test to V1.3.1 from November 2024 instead. You then keep a file that still works after the older row disappears.

What the Two Notices Take Away

Every EN 301 489 entry arrives with the same pair of restrictions. Read both before you treat a listing as a finished argument.

NoticeWhat It SaysWhat You Do About It
Notice 1The standard “does not address emission requirements in frequency bands below 9 kHz and does not therefore confer a presumption of conformity as regards this parameter in this band.”Cover emissions below 9 kHz another way when your product switches or clocks down there.
Notice 2The standard “does not confer a presumption of conformity to the essential requirement set out in Article 3(1), point (b)… if its clause 6 is applied.”Clause 6 holds the performance criteria. Write your own pass/fail reasoning into the technical file rather than pointing to the listing.

Notice 2 catches most engineering teams off guard. The Commission carved out the clause that decides whether your product passed. Your technical file has to carry that call.

The Levels EN 301 489-1 Sets

EN 301 489-1 V2.2.3 holds the test methods every part reuses. Radiated immunity is measured at 3 V/m from 80 MHz to 6 GHz, with 80% amplitude modulation at 1 kHz. Exclusion bands keep your own channel out of the sweep. For a channelized transmitter, that window reaches 250% of the channel width on each side of the center frequency.

PhenomenonLevelApplied To
Radiated RF field3 V/m, 80 MHz to 6 GHzEnclosure
Conducted RF, common mode3 V rms, 150 kHz to 80 MHzWired ports
Electrostatic discharge±4 kV contact and ±8 kV airAccessible surfaces
Electrical fast transient burst1 kVAC mains ports
Electrical fast transient burst0.5 kVDC power ports and signal ports
Surge2 kV line to ground; 1 kV line to lineAC mains ports
Surge0.5 kV line to ground or shield to ground (wired network ports connected to indoor cables)Signal ports
Voltage dip0% residual voltage for 0.5 cycle
0% residual voltage for 1 cycle
70% residual voltage for 25 cycles (at 50 Hz)
0% residual voltage for 250 cycles (at 50 Hz)
AC mains ports

Your part standard then sets the pass mark. EN 301 489-17 V3.3.1 holds equipment that reports errors to a packet or frame error rate of 10% or less while a continuous disturbance runs. A transient disturbance may knock out a function, as long as your product recovers on its own.

What Your Lab Needs From You

The lab tests your radio while it operates, so it tests the states you describe. Thin operating-state notes delay more projects than marginal hardware does. Send these five inputs with your request.

Input You ProvideWhy It Changes the Outcome
Every radio state, idle includedThe lab drives an idle radio too, and background clocks can show up in emissions.
One performance signal to watchClause 6 needs a metric the operator can see, such as packet error rate or link status.
Channel plan with both band edges and a mid-band channelFixes the sweep points and lets the lab work out your exclusion bands.
Transmit duty cycle and timingMatches dwell times to the way your product actually transmits.
Test firmware that matches productionA debug build can invalidate the report.

Send those five, and a first-pass EN 301 489 campaign fits a predictable window. Hold them back, and the chamber waits on your engineers.

MiCOM Labs runs EN 301 489 emissions and immunity in its own chambers in Pleasanton, California. Our reports spell out the clause 6 reasoning your RED technical file needs. Talk to our EMC team about the parts that apply to your product.

Further Reading

Sources